1707 – AdvantagePlus Venting – Sample Views
1707 Technical Bulletin
ABSTRACT: “Many failed igniters, returned in warranty, have failed due to exhaust gas recirculation. Proper installation and using a prescribed termination vent kit will prevent exhaust gas recirculation. “
1709 – Cast Iron Burner Adjustment
1709 Technical Bulletin
ABSTRACT: The natural gas and liquefied petroleum (LP) gas water heaters are equipped with a cast iron burner that requires a primary air adjustment at the time of installation.
1723 – Spiderfire and Initial Installation
1723 Technical Bulletin
ABSTRACT: The most common start up error code is A01 – Maximum Ignition Attempts. This simply means the controller was not able to rectify the main burner flame during an ignition attempt.
1725 – Low Water Cut Off
1725 Technical Bulletin
ABSTRACT: How to Install a Low Water Cut Off switch to a commercial gas water heater.
1729 Troubleshooting Condensate Collector on the Spiderfire
1729 Troubleshooting Condensate Collector on the Spiderfire
ABSTRACT: The condensate collector is a special pan located on the bottom of the Spiderfire. Its job is to collect the condensation that will form in the heat exchanger, flue bundle and venting and then allow for that moisture to be removed.
1734 Ignition Issues with AdvantagePlus
1734 Technical Bulletin
ABSTRACT: Ignition issues with the AdvantagePlus frequently end up with error code F09. This bulletin will help you to troubleshoot the error code.
1739 Spiderfire A06 Fault Code
1739 Technical Bulletin
ABSTRACT: A06 is a fault code indicating a blocked vent. This can mean one of the three pressure switches (Exhaust Vent or Make Up/Intake Air) is at fault.
1741 AdvantagePlus F13 Fault Code
1741 Technical Bulletin
ABSTRACT: The AdvantagePlus blower has an internal over temp switch. If it reaches an overheat condition (a preset temp in that switch) it will shut the blower off. The control board reads blower status by RPM….it sees the blower is not running. It throws an F13 fault code.
1742 Spiderfire Improved Venting Lengths
1742 Technical Bulletin
ABSTRACT: With the recent release of Energy Star SPIDER fire® and new longer equivalent vent lengths, Rheem-Ruud is pleased to announce that most non-Energy Star models will allow longer vent runs too.
1743 Spiderfire A08 Fault Code
1743 Technical Bulletin
ABSTRACT: A08 is now the fault code for “the POF Switch has changed state for 5 seconds during heating cycle.” Effective February 2014, we are now able to distinguish the blower motor from the venting fault codes.
1797 – Triton Leak Testing
1797
ABSTRACT: In response to the new
Triton product line which has the addition of the low gas pressure switch (switch, bushing and tee), please refer to the Use and Care manual regarding leak testing at the time of installation.